Thumbnail 1 Thumbnail 2 Thumbnail 3 Thumbnail 4 Thumbnail 5

Images extracted from submitted plans. See full documents in the attachments section below.

DRB26-1193

3180 NORTH BAY ROAD

The following summaries were generated by AI from the official documents linked below. They may contain errors. Please refer to the original documents for authoritative information.

Proposal

The applicant proposes the construction of a new two-story single-family residence with a roof terrace to replace an existing 1949 residence on a waterfront parcel with frontage on North Bay Road and side-street frontage along Alton Road, with the rear yard abutting Biscayne Bay. The proposal includes three design waiver requests (additional height, front elevation second-floor setback, and side-street elevation second-floor setback) and one variance to reduce the required side setback facing Alton Road from 15 feet to 10 feet. The contemporary design features curved slab edges, broad roof overhangs, extensive glazing, smooth white stucco, bronze-finished mullions, glass railings, and perforated metal panels.

From the Letter of Intent

The project proposes new construction of a two-story single-family residence with a roof terrace and detached summer kitchen, replacing an existing two-story single-family home built in 1949. The home is located in the RS-3 zoning district and features a flat roof with a proposed height of 27 feet. The estimated construction cost is $1,600,000.

  • Demolition of existing two-story single-family home built in 1949
  • New construction of two-story single-family residence
  • Construction of roof terrace
  • Construction of detached summer kitchen
  • Installation of hurricane-impact resistant windows and glazed openings
  • Incorporation of passive cooling systems including operable windows
  • Resilient and native/Florida-friendly landscaping
  • On-site stormwater management system
  • Cool or porous pavement materials in exterior paved areas
  • Critical mechanical and electrical systems located above Base Flood Elevation
Staff Recommendation
APPROVAL W/ CONDITIONS
In view of the foregoing analysis, staff recommends the application be approved with conditions, including the requested waiver and variances, subject to the conditions enumerated in the attached Draft Order, which address the inconsistencies with the aforementioned Design Review, Sea Level Rise criteria and Hardship and Practical Difficulties criteria, as applicable.

Compliance Findings:

✓ Sea Level Rise: Satisfied ✓ Variance Conditions: Satisfied ✗ Design Review Criteria: Not Satisfied
Key Issues
  • Lighting plan has not been submitted (Design Review Criterion i. not satisfied)
  • Waiver requested for additional 3 feet of overall building height above the 24-foot flat roof maximum (proposed 27 feet)
  • Waiver requested to waive the requirement that at least 35% of the second floor along the front elevation be set back a minimum of 5 feet from the minimum required setback
  • Waiver requested to waive the requirement that at least 50% of the second floor along a side elevation facing a street be set back a minimum of 5 feet from the minimum required setback
  • Variance requested to reduce the minimum required 15-foot side facing a street setback to 10 feet due to irregular lot geometry and narrowing frontage toward North Bay Road
  • Final color, design and details of perforated metal panel with faux wood finish require staff review and approval
  • Final color, design and details of steel beams/columns with brake metal finish require staff review and approval
  • Final color, design and details of aluminum mechanical equipment louvers require staff review and approval
Project Details
Style Contemporary, with curved slab edges, broad roof overhangs, extensive glazing, smooth white stucco, bronze-finished window and door mullions, glass railings, steel elements, perforated metal panels with faux-wood finish, and bronze-finished mechanical louvers
Height 27'-0" flat roof (proposed); 24'-0" flat roof (maximum); waiver requested for additional 3 feet
Zoning RS-3
Lot Size 10,270 SF
Setbacks Side facing a street: proposed 10'-0" (variance requested from required 15'-0"); front facade located at 41'-6" setback; second-floor setback waivers requested for both front elevation (35% requirement) and side-street elevation (50% requirement)
Parking Garage positioned near the front of the site with doors perpendicular to North Bay Road; vehicular and pedestrian access provided from North Bay Road
Applicant 3180 HOME LLC
Architect ATELIER305 Architecture+Design (Lester Perez)
Existing Building
Year Built 1949
Architect J. Richard Ogden
Full demolition proposed
Meeting

Thursday, November 19, 2026

09:00 AM

View Full Agenda